Skip to content

VCBATT1_a548 — HV Fault Load Shed

Full alert identifier: VCBATT1_a548_HVFaultLoadShed

Alert description

The low voltage (LV) battery is discharging, even though high voltage (HV) system support has been requested. Vehicle loadshedding will occur, and a separate alert will be present to indicate that condition.

Potential impact

Vehicle loadshedding is triggered, and a separate alert will be present to indicate that condition and its impacts.

Set condition

LV battery is being discharged, even though the HV system should be supporting both the LV battery and the LV bus.

Clear condition

LV battery becomes supported again by the HV system.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Lvbmssoc VCBATT1_a548_LVBMSSOC %
PCS Target Voltage VCBATT1_a548_PCSTargetVoltage V
Amp Hour Bucket Count VCBATT1_a548_ampHourBucketCount Ah
Backstop Bucket Count VCBATT1_a548_backstopBucketCount Ah
Signal Unit
Bms mia VCBATT1_a548_BMS_MIA —
DI Gear VCBATT1_a548_DI_gear
0
INVALID
1
P
2
R
3
N
4
D
7
SNA
—
HV Blocking Mismatch VCBATT1_a548_HVBlockingMismatch —
HV Not Confirmed Up Trigger VCBATT1_a548_HVNotConfirmedUpTrigger —
LV Battery Cannot Support Vehicle VCBATT1_a548_LVBatteryCannotSupportVehicle —
PCSMIA Trigger VCBATT1_a548_PCSMIATrigger —
PCS Not Meeting Target Trigger VCBATT1_a548_PCSNotMeetingTargetTrigger —
PCS Saturated Trigger VCBATT1_a548_PCSSaturatedTrigger —
Show 8 more fields
Signal Unit
Pcs mia VCBATT1_a548_PCS_MIA —
Amp Hour Bucket Filled VCBATT1_a548_ampHourBucketFilled —
Backstop Hit VCBATT1_a548_backstopHit —
Frunk Open VCBATT1_a548_frunkOpen —
Hv State VCBATT1_a548_hvState
0
DOWN
1
COMING UP
2
GOING DOWN
3
UP FOR DRIVE
4
UP FOR CHARGE
5
UP FOR DC CHARGE
6
UP
—
Not Enough Power For Support VCBATT1_a548_notEnoughPowerForSupport —
Service Mode VCBATT1_a548_serviceMode —
Vehicle Power State VCBATT1_a548_vehiclePowerState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a548.

Browse all VCBATT1 alert codes