Skip to content

VCBATT1_a515 — LVBMS Fault MOS Open cell OV

Full alert identifier: VCBATT1_a515_LVBMSFault_MOS_Open_cellOV

Alert description

The low voltage battery management system (LVBMS) reports it has opened the low voltage (LV) battery internal protection transistor (MOSFET) after detecting a cell overvoltage condition.

Potential impact

The LV battery may be damaged and may be unable to support vehicle electrical systems.

Set condition

The LVBMS detects a cell overvoltage condition affecting the LV battery.

Clear condition

The LVBMS reports the cell overvoltage condition is resolved and internal protection transistor (MOSFET) has been requested closed again.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Cell 1 Voltage VCBATT1_a515_cell1Voltage V
Cell 2 Voltage VCBATT1_a515_cell2Voltage V
Cell 3 Voltage VCBATT1_a515_cell3Voltage V
Cell 4 Voltage VCBATT1_a515_cell4Voltage V
Pack SOC VCBATT1_a515_packSOC %
Pack Voltage VCBATT1_a515_packVoltage V
Signal Unit
Frunk Open VCBATT1_a515_frunkOpen —
Service Mode VCBATT1_a515_serviceMode —
Vehicle Power State VCBATT1_a515_vehiclePowerState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a515.

Browse all VCBATT1 alert codes