VCBATT1_a485 — Uv Self Test Load Unattempted On Dbg

Full alert identifier: VCBATT1_a485_uvSelfTestLoadUnattemptedOnDbg

Alert description

One or more loads was not commanded on or did not remain commanded on during the Battery Domain Undervoltage self-test.

Potential impact

Impacted loads may not be turned off as expected. This alert is primarily informational and is used for logging purposes.

Set condition

One or more loads was not commanded on or did not remain commanded on during the Battery Domain Undervoltage self-test.

Clear condition

The Battery Domain Undervoltage self-test runs again and the load is commanded on successfully.

Signals to check

These diagnostic fields are associated with VCBATT1_a485. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Upstream Efuse Unattempted On VCBATT1_a485_upstreamEfuseUnattemptedOn —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a485.