VCBATT1_a485 — Uv Self Test Load Unattempted On Dbg
Full alert identifier: VCBATT1_a485_uvSelfTestLoadUnattemptedOnDbg
Alert description
One or more loads was not commanded on or did not remain commanded on during the Battery Domain Undervoltage self-test.
Potential impact
Impacted loads may not be turned off as expected. This alert is primarily informational and is used for logging purposes.
Set condition
One or more loads was not commanded on or did not remain commanded on during the Battery Domain Undervoltage self-test.
Clear condition
The Battery Domain Undervoltage self-test runs again and the load is commanded on successfully.
Signals to check
These diagnostic fields are associated with VCBATT1_a485. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Upstream Efuse Unattempted On
VCBATT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a485.