VCBATT1_a433 — T LVBMS Config From Bmb Mod Id Failed
Full alert identifier: VCBATT1_a433_TLVBMS_ConfigFromBmbModIdFailed
Alert description
The installed battery does not have a supported BMB identifier
Potential impact
BMS firmware will select default config parameters which may not correspond to the actual battery type installed. Battery signals may be missing or incorrect
Set condition
A battery is installed with an unsupported BMB identifier
Clear condition
A battery is installed with a supported BMB identifier
Signals to check
These diagnostic fields are associated with VCBATT1_a433. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bmb Module Id
VCBATT1_
|
— |
Bmb Module Id Valid
VCBATT1_
|
— |
Cell Type Data
VCBATT1_
|
— |
Pack Type Data
VCBATT1_
|
— |
Use Bmb Module Id
VCBATT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a433.