VCBATT1_a388 — Shorted Cell

Full alert identifier: VCBATT1_a388_shortedCell

Alert description

The low voltage (LV) battery has failed a test 5 times that checks for shorted battery cells. May indicate the LV battery has at least one shorted cell and is unable to fully support the LV electrical system. Note: A single failure of this test does not reliably indicate a condition affecting LV battery function. Only after 5 failed tests will the vehicle controller set this alert.

Potential impact

The LV battery has at least one shorted cell, which could prevent it from adequately supporting the vehicle's electrical systems.

Set condition

The LV battery has failed a shorted cell test at least 5 times. Alert log signal data should provide more information, including the load current, battery temperature, and voltage dip measured during testing.

Clear condition

The vehicle controller loses all electrical power from the LV battery and power conversion system (PCS), as would happen during LV battery replacement.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
IBS Temp VCBATT1_a388_IBSTemp degC
Max Current Reached VCBATT1_a388_maxCurrentReached A
Min Voltage Reached VCBATT1_a388_minVoltageReached V
Shorted Cell Fault Counter VCBATT1_a388_shortedCellFaultCounter —
Signal Unit
Opportunistic Test VCBATT1_a388_opportunisticTest —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a388.