VCBATT1_a224 — Overcurrent Loadshed Triggered
Full alert identifier: VCBATT1_a224_overcurrentLoadshedTriggered
Alert description
Overcurrent loadshed protection has tripped on the Battery Vehicle Controller (VCBATT).
Potential impact
Impacted load(s) unavailable in Drive.
Set condition
Overcurrent detected by VCBATT while the vehicle is in Drive.
Clear condition
Overcurrent loadshed protection resets when the vehicle is out of drive
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Oc Sense Amp Current
VCBATT1_
|
A |
| Signal | Unit |
|---|---|
Fault Channel Pin Active Fast
VCBATT1_
|
— |
Fault Channel Pin Active Ingoing
VCBATT1_
|
— |
Fault Channel Pin Active Medium
VCBATT1_
|
— |
Fault Channel Pin Active Slow
VCBATT1_
|
— |
Hardware Loadshed Fault Active
VCBATT1_
|
— |
Hardware Loadshed Fault Active Ingoing
VCBATT1_
|
— |
Oc Loadshed Fault Active
VCBATT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a224.