VCBATT1_a191 — Exit Drive Low LV Bus Voltage
Full alert identifier: VCBATT1_a191_exitDriveLowLVBusVoltage
Message shown in the car
Electrical system power reduced Vehicle shutting down
Alert description
An issue with the low voltage (LV) electrical system requires the vehicle to come to a stop immediately. The vehicle should enter graceful power-off (GPO) to exit drive, and a separate alert should indicate that condition.
Potential impact
The vehicle will not enter drive. If the vehicle is driving, it will exit drive through graceful power-off (GPO) to come to a stop immediately. A separate alert should be present to indicate the GPO
Set condition
Lead acid: Low voltage (LV) battery voltage below threshold for 3 seconds (3s); transistor gating LV battery connection is open (no current flow); vehicle load shedding is active; or reverse battery transistor issue detected.
Clear condition
Low voltage (LV) battery voltage above threshold; transistor gating LV battery connection is closed; no reverse battery transistor issue detected; vehicle loadshedding is not active.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
IBS Voltage
VCBATT1_
|
V |
LVBMS Voltage
VCBATT1_
|
V |
| Signal | Unit |
|---|---|
ECPA State
VCBATT1_
|
— |
LVBMS Current Target Valid
VCBATT1_
|
— |
Lvbmsmia
VCBATT1_
|
— |
LVBMS Voltage Target Valid
VCBATT1_
|
— |
MOS State
VCBATT1_
|
— |
Not Enough Power For Support
VCBATT1_
|
— |
Pcs mia
VCBATT1_
|
— |
A 180 DCDC Not Supporting LV Bus
VCBATT1_
|
— |
Show 11 more fields
| Signal | Unit |
|---|---|
Bms State
VCBATT1_
|
— |
Exit Drive Warning Timer Expired
VCBATT1_
|
— |
Frunk Open
VCBATT1_
|
— |
Hv State
VCBATT1_
|
— |
Reverse Battery E Fuse Fault
VCBATT1_
|
— |
Service Mode
VCBATT1_
|
— |
Vehicle Load Shed Active
VCBATT1_
|
— |
Vehicle Load Shed Hv Fault Active
VCBATT1_
|
— |
Vehicle Load Shed Post Crash Active
VCBATT1_
|
— |
Vehicle Load Shed Stage
VCBATT1_
|
— |
Vehicle Power State
VCBATT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a191.