Skip to content

VCBATT1_a182 — Replace LV Battery

Full alert identifier: VCBATT1_a182_replaceLVBattery

Message shown in the car

Schedule service to replace low voltage battery Software will not update until battery is replaced

Alert description

The Low Voltage (LV) battery needs to be replaced.

Potential impact

The LV battery may lack the power to support vehicle auxiliary systems. The vehicle may be unable to start and range loss may be experienced.

Set condition

LV battery diagnosed as needing replacement to maintain full vehicle functionality

Clear condition

Vehicle LV power disconnect procedure is performed (as would happen during LV battery replacement).

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ambient Temp VCBATT1_a182_ambientTemp
0
SNA
degC
Charged Amp Hours VCBATT1_a182_chargedAmpHours Ah
Discharged Amp Hours VCBATT1_a182_dischargedAmpHours Ah
Signal Unit
LV Floor Reached VCBATT1_a182_LVFloorReached —
Battery Type VCBATT1_a182_batteryType
0
UNKNOWN
1
ATLASBX B24 FLOODED
2
CLARIOS B24 FLOODED
3
CATL LI ION
4
TESLA 16V LI ION
5
TESLA 48V LI ION
—
Bleed Fet Test Failure VCBATT1_a182_bleedFetTestFailure —
Brick Over Discharged VCBATT1_a182_brickOverDischarged —
Calibration Lost Fault VCBATT1_a182_calibrationLostFault —
Cell Imbalance VCBATT1_a182_cellImbalance —
Dcr Milli Ohms Above Threshold VCBATT1_a182_dcrMilliOhmsAboveThreshold —
Dead LV VCBATT1_a182_deadLV —
Show 15 more fields
Signal Unit
Factory Mode VCBATT1_a182_factoryMode —
Frunk Open VCBATT1_a182_frunkOpen —
Impedance Growth VCBATT1_a182_impedanceGrowth —
Instant Precharge DCR Too High VCBATT1_a182_instantPrechargeDCRTooHigh —
Overcharge VCBATT1_a182_overcharge —
Pack Over Discharged VCBATT1_a182_packOverDischarged —
Post POR Excessive Ah VCBATT1_a182_postPORExcessiveAh —
Precharge LV Load Reduction VCBATT1_a182_prechargeLVLoadReduction —
Resistance Estimation Hard Failure VCBATT1_a182_resistanceEstimationHardFailure —
Sampling HW Error VCBATT1_a182_samplingHWError —
Service Mode VCBATT1_a182_serviceMode —
Shorted Cell VCBATT1_a182_shortedCell —
Transport Mode VCBATT1_a182_transportMode —
Voltage Drop VCBATT1_a182_voltageDrop —
Weak Short VCBATT1_a182_weakShort —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a182.

Browse all VCBATT1 alert codes