Skip to content

TRCM_a200 — Right B Pillar Accel Reported Error

Full alert identifier: TRCM_a200_rightBPillarAccelReportedError

Alert description

An error condition affecting the right B-pillar accelerometer impact sensor's communication channel is detected.

Potential impact

The Safety Restraint System may not perform as designed.

Set condition

An error condition is detected on the right B-pillar accelerometer impact sensor's communication channel. Alert log signal data should provide more information on specific condition(s) involved.

Clear condition

The error condition affecting the right B-pillar accelerometer impact sensor is no longer detected.

Signals to check

These diagnostic fields are associated with TRCM_a200. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Channel Off TRCM_a200_channelOff —
Current High TRCM_a200_currentHigh —
Invalid Data TRCM_a200_invalidData —
No Data TRCM_a200_noData —
Over Temperature TRCM_a200_overTemperature —
Wrong Time Slot TRCM_a200_wrongTimeSlot —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TRCM_a200.

Browse all TRCM alert codes