TRCM_a175 — Left C Pillar Accel Reported Error

Full alert identifier: TRCM_a175_leftCPillarAccelReportedError

Alert description

An error condition affecting the left C-pillar accelerometer impact sensor's communication channel is detected.

Potential impact

The Safety Restraint System may not perform as designed.

Set condition

An error condition is detected on the left C-pillar accelerometer impact sensor's communication channel. Alert log signal data should provide more information on specific condition(s) involved.

Clear condition

The error condition affecting the left C-pillar accelerometer impact sensor is no longer detected.

Signals to check

These diagnostic fields are associated with TRCM_a175. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Channel Off TRCM_a175_channelOff —
Current High TRCM_a175_currentHigh —
Invalid Data TRCM_a175_invalidData —
No Data TRCM_a175_noData —
Over Temperature TRCM_a175_overTemperature —
Wrong Time Slot TRCM_a175_wrongTimeSlot —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TRCM_a175.