Skip to content

TRCM_a155 — Front Left Door Pressure Reported Error

Full alert identifier: TRCM_a155_frontLeftDoorPressureReportedError

Alert description

An error condition affecting the front left door pressure impact sensor's communication channel is detected.

Potential impact

The Safety Restraint System may not perform as designed.

Set condition

An error condition is detected on the front left door pressure impact sensor's communication channel. Alert log signal data should provide more information on specific condition(s) involved.

Clear condition

The error condition affecting the front left door pressure impact sensor is no longer detected.

Signals to check

These diagnostic fields are associated with TRCM_a155. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Channel Off TRCM_a155_channelOff —
Current High TRCM_a155_currentHigh —
Invalid Data TRCM_a155_invalidData —
No Data TRCM_a155_noData —
Over Temperature TRCM_a155_overTemperature —
Wrong Time Slot TRCM_a155_wrongTimeSlot —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TRCM_a155.

Browse all TRCM alert codes