Skip to content

TAS_a072 — Short Circuit5 V On Board

Full alert identifier: TAS_a072_shortCircuit5VOnBoard

Alert description

On board 5V switched supply is measured to be approximately 0V.

Potential impact

Air suspension leveling will be disabled. Systems with adaptive dampers will disable the dampers.

Set condition

On board 5V switched supply is measured to be approximately 0V.

Clear condition

Vehicle-power-state cycle from off to on.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Voltage 5 V On Board TAS_a072_voltage5VOnBoard V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a072.

Browse all TAS alert codes