Skip to content

TAS_a039 — PW Mopen FR

Full alert identifier: TAS_a039_PWMopenFR

Alert description

Front right height sensor disconnected, or signal line from front right Pulse Width Modulation (PWM) height sensor floating.

Potential impact

Air suspension leveling will be disabled. Systems with adaptive dampers will disable active damping control.

Set condition

Front right height sensor disconnected, or signal line from front right PWM height sensor floating.

Clear condition

Expected PWM signal received from front right ride height sensor.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
PW Mduty Cycle FR TAS_a039_PWMdutyCycleFR %
PW Mfrequency FR TAS_a039_PWMfrequencyFR Hz
Signal Unit
PW Mfault FR TAS_a039_PWMfaultFR —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a039.

Browse all TAS alert codes