SCCM_a061 — Voltage High 2

Full alert identifier: SCCM_a061_voltageHigh_2

Alert description

Steering Column Control Module (SCCM) input voltage is above the expected operating range.

Potential impact

Steering or turn indicator stalk may not operate as expected.

Set condition

SCCM detects an input voltage greater than 16.7V for 15 seconds.

Clear condition

SCCM detects an input voltage less than 16.2V for 1 second.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SCCM_a061.