Skip to content

PM_a084 — Exception Mpu Firewall

Full alert identifier: PM_a084_exceptionMpuFirewall

Alert description

The Pedal Monitor (PM) processor has detected an internal exception. This alert does not on its own indicate a symptom or root cause.

Potential impact

This alert is primarily informational and is used for logging purposes.

Set condition

The PM processor detects an exception.

Clear condition

This alert clears automatically.

Signals to check

These diagnostic fields are associated with PM_a084. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Fault Address PM_a084_faultAddress —
Fault Type PM_a084_faultType
0
NO FAULT
1
USER EXE
2
USER WRITE
3
USER READ
4
SUPER EXE
5
SUPER WRITE
6
SUPER READ
—
Firewall Id PM_a084_firewallId —
Ns PM_a084_ns —
Priv Id PM_a084_privId
1
M4FSS0 0
4
R5FSS0 0
5
R5FSS0 1
6
R5FSS1 0
7
R5FSS1 1
9
ICSSM
10
CPSW
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PM_a084.

Browse all PM alert codes