Skip to content

PMR_a101 — Hw Voltage Monitor Trip

Full alert identifier: PMR_a101_hwVoltageMonitorTrip

Alert description

The Error Signal Module (ESM) Voltage Monitor (VMON) module detected under/overvoltage on one or more of the following rails: VDDA 1.8V, VBGAP 0.9V, VDD 1.2V, IO BIAS, external supply monitor, VDDA 3.3V, ADC0, ADC1/2, ADC3/4, or ADC_R0/1.

Potential impact

The processor is put into a safe state as a result of the under/overvoltage.

Set condition

Any of the relevant ESM VMON status registers indicate under/overvoltage.

Clear condition

All the relevant ESM VMON status registers indicate nominal voltage.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMR_a101.

Browse all PMR alert codes