PCS2_a146 — Ac Line Shared Current Connection Issue
Full alert identifier: PCS2_a146_acLineSharedCurrentConnectionIssue
Alert description
The Power Conversion System (PCS2) detects that the DCAC converter's shared leg current is not shared evenly when the legs are shorted by either the AC harness or the AC relay.
Potential impact
The DCAC converters will have reduced power capabilities.
Set condition
The shared leg current difference exceeds the expected threshold.
Clear condition
The shared leg current is an even split of the total current.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Leg 1 Irms
PCS2_
|
A |
Leg 2 Irms
PCS2_
|
A |
Leg 3 Irms
PCS2_
|
A |
Leg N Irms
PCS2_
|
A |
| Signal | Unit |
|---|---|
Ac Harness L 2 L 3 Shorted
PCS2_
|
— |
Legs Paralleled By Relay
PCS2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a146.