Skip to content

PCS2_a132 — Microgrid Droop Detected

Full alert identifier: PCS2_a132_microgridDroopDetected

Message shown in the car

Vehicle charging with off-grid Powerwall Charging rate adjusted to allow power sharing

Alert description

The Power Conversion System (PCS2) detects the microgrid frequency droops below its nominal level indicating microgrid is under heavy load

Potential impact

AC charging power will be temporarily limited depending on the droop level to reduce the load on the microgrid

Set condition

The PCS2 ECU detects the microgrid frequency droops below its nominal level

Clear condition

Microgrid no longer detected

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
L 1 N Grid Voltage PCS2_a132_L1NGridVoltage V
L 2 N Grid Voltage PCS2_a132_L2NGridVoltage V
L 3 N Grid Voltage PCS2_a132_L3NGridVoltage V
Current Limit PCS2_a132_currentLimit A
Grid Frequency PCS2_a132_gridFrequency Hz

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a132.

Browse all PCS2 alert codes