Skip to content

ESP_a377 — PM loc State DLC

Full alert identifier: ESP_a377_PM_locStateDLC

Alert description

Data length code error detected on Pedal Monitoring message PM_locState.

Potential impact

System will be running with full power brake assistant for driver brake request.

Set condition

Data length code error detected on Pedal Monitoring message PM_locState.

Clear condition

No internal issue is detected after changing operation cycle.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of ESP_a377.

Browse all ESP alert codes