ESP_a365 — TCS Input Quality Too Low

Full alert identifier: ESP_a365_TCSInputQualityTooLow

Alert description

Input signal for TCS function not good enough.

Potential impact

Functions in ESP will be available still.

Set condition

TCS controller is deactivated temporarily due to low input signal quality of Wheel Speed Sensor (WSS) (OR)TCS controller is deactivated temporarily due to low input signal quality of Power Train Component (PT), The monitoring is active when TCS controller is enabled.

Clear condition

The monitoring is healed when TCS controller is enabled and the signal quality is good for a certain time.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of ESP_a365.