Skip to content
Model Y

EPASTS_a261 — Sccm Status Error

Full alert identifier: EPASTS_a261_sccmStatusError

Alert description

This alert is reported when the steeting angle sensor status QF signal is detected faulted

Potential impact

If since from startUp, impact on Steering Angle Sensor Synchronization. Impact on the internalSASQF.

Set condition

SCCM_steeringAngleSensorStatus message received with ERROR_INIT or ERROR for longer than tolerated time.

Clear condition

SCCM_steeringAngleSensorStatus message received with OK.

Signals to check

These diagnostic fields are associated with EPASTS_a261. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a261_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a261.