EPASTS_a261 — Sccm Status Error
Full alert identifier: EPASTS_a261_sccmStatusError
Alert description
This alert is reported when the steeting angle sensor status QF signal is detected faulted
Potential impact
If since from startUp, impact on Steering Angle Sensor Synchronization. Impact on the internalSASQF.
Set condition
SCCM_steeringAngleSensorStatus message received with ERROR_INIT or ERROR for longer than tolerated time.
Clear condition
SCCM_steeringAngleSensorStatus message received with OK.
Signals to check
These diagnostic fields are associated with EPASTS_a261. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a261.