EPASTS_a205 — Fdr Ocl Fail
Full alert identifier: EPASTS_a205_fdrOclFail
Alert description
This alert is reported by the Output Control Logic (OCL) of the FdrDetectionManager_R12 (FDR) component when the necessary signals for freezing and retention detection are not available.
Potential impact
Freezing detection and retention inhibited.
Set condition
EPAS application diagnostics detected freezing temperature problem (missing sensor signals - MotorAngle/MotorAngleSpeed).
Clear condition
Inputs become valid again. (MotorAngle/MotorAngleSpeed signal diagflags are not indicating error anymore.
Signals to check
These diagnostic fields are associated with EPASTS_a205. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a205.