Skip to content
Model Y

EPASTS_a186 — Wdh Comm Buffer Overflow

Full alert identifier: EPASTS_a186_wdhCommBufferOverflow

Alert description

This alert is reported by the WatchdogHandler_A8140x (WDH) component in case SBC Communication buffer overflow checker. Against systematic SW failures on WatchdogHandler component.

Potential impact

EPAS reset. If reset more than 5 times then EPAS full loss of assist.

Set condition

SBC Communication buffer is overflow (RTE buffer (message queue) overflow in the WatchdogHandler_A8140x component).

Clear condition

EPAS will perform a power cycle. If persist then perform EPAS Software update.

Signals to check

These diagnostic fields are associated with EPASTS_a186. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a186_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a186.

Browse all EPASTS alert codes