EPASTS_a182 — Mcd Input Mia
Full alert identifier: EPASTS_a182_mcdInputMia
Alert description
This alert is reported by the MotorControlDiagnostics_R12 (MCD) component if MTCControlSignal age reached the diagnostic limit.
Potential impact
EPAS reset. If reset more than 5 times then EPAS full loss of assist.
Set condition
EPAS motor control diagnostics detected requested motor torque timeout (signal age reached the diagnostic limit).
Clear condition
EPAS will perform a power cycle.
Signals to check
These diagnostic fields are associated with EPASTS_a182. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a182.