Skip to content
Model Y

EPASTS_a177 — Etsr Invalidated

Full alert identifier: EPASTS_a177_etsrInvalidated

Alert description

This alert is reported when the ElapsedTimeSinceReset (ETSR) counter becomes greater than the ETSR_THRESHOLD_TIMESTAMP and counter forced to 0xFFFFFFFF

Potential impact

EPAS QM reset when is less likely to disturb the driver. If it is not possible, there will be incoming communication freeze and a reset.

Set condition

EPAS elapsed time since reset (ETSR) counter becomes greater than the tolarated limit and counter forced to 0xFFFFFFFF.

Clear condition

EPAS power cycle.

Signals to check

These diagnostic fields are associated with EPASTS_a177. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a177_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a177.

Browse all EPASTS alert codes