EPASTS_a134 — Oseh Guarded Reset After Err Without Reset

Full alert identifier: EPASTS_a134_osehGuardedResetAfterErrWithoutReset

Alert description

This alert is reported by the OsErrorHandler_R12(OSEH) component when ErrorHook was called because of an error in a partition which is configured to handle such errors with requesting a guarded reset. This error is reported after the guarded reset.

Potential impact

EPAS reset.

Set condition

If any OS service returns a StatusType value other value than E_OK. The error is reported after a guarded reset caused by OS error.

Clear condition

Perform EPAS Software update.

Signals to check

These diagnostic fields are associated with EPASTS_a134. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a134_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a134.