Skip to content
Model Y

EPASTS_a115 — Mcussc Lbist Single Fail

Full alert identifier: EPASTS_a115_mcusscLbistSingleFail

Alert description

This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when there is a MCU failure. Logic built-in self-test failed.

Potential impact

EPAS reset. If reset more than 3 then EPAS full loss of assist.

Set condition

EPAS logic built-in self-test failed.

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTS_a115. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a115_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a115.

Browse all EPASTS alert codes