EPASTS_a091 — Bvp Batt Volt Cross Chk Failed

Full alert identifier: EPASTS_a091_bvpBattVoltCrossChkFailed

Alert description

This alert is reported by the BatteryVoltageProvider_R12 (BVP) component when the voltage measurement comparison (battery vs bridge) failed.

Potential impact

EPAS full loss of assist.

Set condition

EPAS battery voltage measurement and bridge voltage measurement comparison failed.

Clear condition

Absolute difference of Battery and Bridge voltage is less or equal than D2008_MaxVoltageDiff Volts and qualifiers are reliable.

Signals to check

These diagnostic fields are associated with EPASTS_a091. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a091_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a091.

Browse all EPASTS alert codes