EPASTS_a085 — Am Gdu Switch Off Test By Mcu

Full alert identifier: EPASTS_a085_amGduSwitchOffTestByMcu

Alert description

This alert is reported by the ActuatorManager_R12 (AM) component when there is a GDU or GDU-MCU connection problem. This diagnostic checks if the microcontroller is able to switch off the GDU.

Potential impact

EPAS full loss of assist.

Set condition

EPAS Gate Driver switch-off test by MCU fails. GDU is unable to switch off the GDU.

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTS_a085. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a085_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a085.

Browse all EPASTS alert codes