Skip to content
Model Y

EPASTS_a058 — Am Int Vgs Undervtg Err

Full alert identifier: EPASTS_a058_amIntVgsUndervtgErr

Alert description

This alert is reported by the ActuatorManager_R12 (AM) component when there is a GDU failure. GDU monitors gate-to-source voltage, sets a flag and the software checks it.

Potential impact

EPAS full loss of assist.

Set condition

EPAS ECU GDU device monitor detected failure (gate-to-source voltage).

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTS_a058. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a058_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a058.

Browse all EPASTS alert codes