Skip to content
Model Y

EPASTS_a045 — Psum Sbc Bandgap Volt Err

Full alert identifier: EPASTS_a045_psumSbcBandgapVoltErr

Alert description

This alert is reported by the PowerSupplyManager_R12 (PSUM) when there is a SBC internal failure.

Potential impact

EPAS full loss of assist.

Set condition

EPAS ECU SBC device internal voltage monitoring failure (VMON_bandgap out of tolerated limit) at startup.

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTS_a045. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a045_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a045.

Browse all EPASTS alert codes