Alert description

This alert is reported by SMUHandler_TC3X (SMUH) component when SMU Core alive test is failed.

Potential impact

EPAS full loss of assist.

Set condition

EPAS uC peripheral (SMU core) alive test failure at startup, before start of OS.

Clear condition

Perform EPAS Software update at first, replace HW if the alert appears again.

Signals to check

These diagnostic fields are associated with EPASTS_a029. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a029_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a029.