Skip to content
Model Y

EPASTS_a028 — Smuh Non Init Data Corruption

Full alert identifier: EPASTS_a028_smuhNonInitDataCorruption

Alert description

This alert is reported by the SMUHandler_TC3X (SMUH) component when SMU Core Alive test data integrity check fails (comparison with the inverted value).

Potential impact

EPAS full loss of assist.

Set condition

EPAS uC peripheral (SMU) alive test failure (data corruption, inverted value comparison) at startup.

Clear condition

Perform EPAS Software update.

Signals to check

These diagnostic fields are associated with EPASTS_a028. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a028_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a028.

Browse all EPASTS alert codes