Skip to content
Model Y

EPASTP_a183 — Sbch Comm Err Sbc To Mcu

Full alert identifier: EPASTP_a183_sbchCommErrSbcToMcu

Alert description

This alert is reported by the SystemBasisChipHAL_A8140x (SBCH) component SBC if the communication check (SBC -> MCU) fails. Against random HW failures of the MCU and communication line including EMC.

Potential impact

EPAS reset. If reset more than 5 times then EPAS full loss of assist.

Set condition

EPAS SBC diagnostics detected SPI failures. Communication check (SBC -> MCU) fails (Wrong ID or CRC failure).

Clear condition

EPAS will perform a power cycle. If persist then perform EPAS Software update. Replace HW if the alert persist.

Signals to check

These diagnostic fields are associated with EPASTP_a183. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a183_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a183.

Browse all EPASTP alert codes