Alert description

This alert is reported by the MotorControlDiagnostics_R12 (MCD) component if MTCControlSignal age reached the diagnostic limit.

Potential impact

EPAS reset. If reset more than 5 times then EPAS full loss of assist.

Set condition

EPAS motor control diagnostics detected requested motor torque timeout (signal age reached the diagnostic limit).

Clear condition

EPAS will perform a power cycle.

Signals to check

These diagnostic fields are associated with EPASTP_a182. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a182_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a182.