EPASTP_a159 — Exch Flash Wordline Transient Err
Full alert identifier: EPASTP_a159_exchFlashWordlineTransientErr
Alert description
This alert is reported by the ExceptionHandler_TC3x (EXCH) component when there is a double bit ECC error in the active pflash and additional ECC errors were found in the same wordline
Potential impact
EPAS full loss of assist.
Set condition
EPAS application component ExceptionHandler detected unrecoverable memory failure (other page PFlash ECC fault).
Clear condition
Perform EPAS Software update. Replace HW if the alert persists.
Signals to check
These diagnostic fields are associated with EPASTP_a159. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a159.