Skip to content
Model Y

EPASTP_a155 — Sdsm Data Invalid All

Full alert identifier: EPASTP_a155_sdsmDataInvalidAll

Alert description

This alert is reported by the StreamingDataStorageManager_R12 (SDSM) component when the CRC is not equal to saved CRC value in all memory blocks.

Potential impact

EPAS fast restart was not possible.

Set condition

EPAS streaming data storage manager component detects CRC failure and restoration was not possible.

Clear condition

Perform EPAS Software update. Replace HW if the alert persists.

Signals to check

These diagnostic fields are associated with EPASTP_a155. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a155_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a155.

Browse all EPASTP alert codes