Skip to content
Model Y

EPASTP_a146 — Btarc Rc Circuit Check

Full alert identifier: EPASTP_a146_btarcRcCircuitCheck

Alert description

This alert is reported by the BlackoutTimeAndResetCounter_R12 (BTARC) component when analog restart timer is working incorrectly. This diagnostic checks if the analog restart timer is working correctly.

Potential impact

EPAS will not attempt fast restart.

Set condition

EPAS application BTARC management failure (timer restart).

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTP_a146. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a146_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a146.

Browse all EPASTP alert codes