EPASTP_a136 — Ft Electrical Angle Qf

Full alert identifier: EPASTP_a136_ftElectricalAngleQf

Alert description

This alert is reported by the FrequencyTransformer_R12 (FT) component when the electrical angle QoS is Substitute Value or Error and RotorPositionAge tolerance time elapsed. This diagnostic compares the 2 local RPSs, and compares the local RPSs and the remote one. If no RPS is available or it is not decidable which RPS is usable, it signals this.

Potential impact

Unreliable absolute steering position provision qualifier. Virtual End Lock deactivation.

Set condition

Electrical angle QoS is Substitute Value or Error and RotorPositionAge tolarence time elapsed.

Clear condition

Electrical angle QoS is Reliable.

Signals to check

These diagnostic fields are associated with EPASTP_a136. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a136_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a136.

Browse all EPASTP alert codes