EPASTP_a101 — Sdrv Spc Id Mismatch

Full alert identifier: EPASTP_a101_sdrvSpcIdMismatch

Alert description

This alert is reported by the SENTDriverCD_TC3x component when there is a TSU sensor failure or connection failure.

Potential impact

Torque sensor failed but EPAS still can operate normal.

Set condition

TSU sensor failure or connection failure. EPAS ECU TSU device monitor detected sensor failure.

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTP_a101. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a101_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a101.