EPASTP_a068 — Rsth Core Redundancy Err
Full alert identifier: EPASTP_a068_rsthCoreRedundancyErr
Alert description
This alert is reported by the HwResetHandler_TC3x (RSTH) component when there is a Lockstep failure: cores no longer synchronized or provided different values.
Potential impact
EPAS reset
Set condition
EPAS uC dual core lockstep fault (cores no longer sync).
Clear condition
EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.
Signals to check
These diagnostic fields are associated with EPASTP_a068. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a068.