EPASTP_a058 — Am Int Vgs Undervtg Err
Full alert identifier: EPASTP_a058_amIntVgsUndervtgErr
Alert description
This alert is reported by the ActuatorManager_R12 (AM) component when there is a GDU failure. GDU monitors gate-to-source voltage, sets a flag and the software checks it.
Potential impact
EPAS full loss of assist.
Set condition
EPAS ECU GDU device monitor detected failure (gate-to-source voltage).
Clear condition
EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.
Signals to check
These diagnostic fields are associated with EPASTP_a058. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a058.