Alert description

This alert is reported by the SafetyRelayHAL_R12 (SRH) component if the CRC calculation of the SEC_VAR_SRH_BIST_STATUS memory section is failed or the CRC validity pattern is invalid. During the startup SafetyRelayHAL_R12_RestoreRelays function stores the state of the non-initialized data integrity (corrupted or not) in the SRH_D8037_Status variable and this is evaluated after RTE has been started.

Potential impact

EPAS full loss of assist.

Set condition

EPAS uC internal memory (safety relay management storage) failure (CRC) at startup.

Clear condition

Perform EPAS Software update.

Signals to check

These diagnostic fields are associated with EPASTP_a024. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a024_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a024.