EPASTP_a014 — Mcussc Sff Monitoring Mia
Full alert identifier: EPASTP_a014_mcusscSffMonitoringMia
Alert description
This alert is reported by the MCUSafetyStartupChecks_TC3x (MCUSSC) component when there is a MCU internal failure (The Safety FlipFlop Monitoring tests not finished in time).
Potential impact
EPAS full loss of assist.
Set condition
EPAS Safety FlipFlop Monitoring timeout at startup.
Clear condition
Perform EPAS ECU power cycle.
Signals to check
These diagnostic fields are associated with EPASTP_a014. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a014.