Skip to content

DPB_a310 — DIR Axle Torque Invalid

Full alert identifier: DPB_a310_DIRAxleTorqueInvalid

Alert description

Invalid Drive Inverter Rear (DIR) drive torque signal or qualifier (QF) is received.

Potential impact

The Decoupled Power Brake (DPB) may not generate brake torque requested by DI_brakeTorqueCommandFull and instead generate brake torque requested by DI_brakeTorqueCommand. There may be an issue with the transmitting Electronic Control Unit (ECU).

Set condition

The Decoupled Power Brake (DPB) receives either the DIR_torqueActual Controller Area Network (CAN) signal as Signal Not Available (SNA) or the DIR_axleTorqueQF CAN signal as INVALID or FAULTED for longer than 100 milliseconds.

Clear condition

Valid DIR_torqueActual and Valid DIR_axleTorqueQF are received for 100 milliseconds.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a310.

Browse all DPB alert codes