Skip to content

DPB_a130 — Asic Malfunction Detected

Full alert identifier: DPB_a130_AsicMalfunctionDetected

Alert description

On the system ASIC an overcurrent event occured. The General Purpose Input Output (GPIO) is not operating as expected.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

This fault will be reported if the GPIO is switched off but the overcurrent bit of the ASIC remains set (GPIO is not operating as expected).

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a130.

Browse all DPB alert codes