Skip to content

DPB_a018 — Large Leakage Detected Good Check

Full alert identifier: DPB_a018_largeLeakageDetectedGoodCheck

Alert description

Large Leakage can be caused by internal or external loss of brake fluid. GoodCheck is required.

Potential impact

System will be running with internal degraded pedal map. Braking may require increased effort.

Set condition

Plunger is not possible to build up necessary pressure in brake system. Caused by: Significant loss of brake fluid - external (broken brake pipe) or internal (seal or valve defect). Large Leakage alert is assumed if the pressure sensor shows significant lower values than expected at maximum possible plunger position.

Clear condition

Good check is performed with applying the brake for min. 30 bar and for 3 sec.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a018.