CP_a210 — Lost Comms PCSR
Full alert identifier: CP_a210_lostCommsPCSR
Alert description
The Charge Port (CP) Electronic Control Unit (ECU) loses communication with the Right Power Conversion System (PCSR).
Potential impact
Electric Power Take Off does not start.
Set condition
The CP ECU does not receive all expected CAN messages from the PCSR.
Clear condition
Clears when the CP ECU receives all expected CAN messages from the PCSR.
Signals to check
These diagnostic fields are associated with CP_a210. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
PCS 2 R V 2 X Info 2 MIA
CP_
|
— |
PCS 2 R V 2 X Info MIA
CP_
|
— |
PCSR Chg Status MIA
CP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a210.