Skip to content

CP_a058 — Ac Charge Retry Pending

Full alert identifier: CP_a058_acChargeRetryPending

Message shown in the car

Unable to AC charge - System will retry shortly Disconnect and retry or use different equipment

Alert description

The charge port (CP) electronic control unit (ECU) will delay an attempt to AC charge

Potential impact

Charging does not start or is interrupted.

Set condition

The CP ECU detects that the electric vehicle supply equipment (EVSE) has encountered an issue too many times while AC charging.

Clear condition

The CP ECU detects that the charge cable has been unplugged or there is no longer a retry delay

Signals to check

These diagnostic fields are associated with CP_a058. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
CC Pilot CP_a058_CC_pilot
0
READY
1
IDLE
2
FAULTED
3
SNA
—
CP Pilot CP_a058_CP_pilot
0
NONE
1
FAULTED
2
LINE CHARGE
3
FAST CHARGE
4
IDLE
5
INVALID
6
UNUSED 6
7
SNA
—
CP Proximity CP_a058_CP_proximity
0
SNA
1
DISCONNECTED
2
UNLATCHED
3
LATCHED
—
FC Status CP_a058_FC_status —
Ac Num Retries CP_a058_acNumRetries —
Ac Retry Timeout S CP_a058_acRetryTimeoutS —
Latch State CP_a058_latchState
0
SNA
1
DISENGAGED
2
ENGAGED
3
BLOCKING
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a058.

Browse all CP alert codes