Alert Description
The Autopilot electronic control unit (ECU) detects a physical connection issue between the camera quad hub's deserializer and one or more cameras, causing camera initialization failure(s).
Potential Impact
Autopilot features may be unavailable, or may not function as expected.
Set condition
The Autopilot ECU detects the camera quad hub deserializer's power signal as low, potentially due to camera physical connection issues.
Clear condition
Clears when the Autopilot ECU detects the camera quad hub deserializer's power signal as high, indicating all four cameras are connected properly.